общие_настройки_сетевого_оборудования_cisco [2022/03/14 13:28]
val [Использование RMON подсистемы протокола SNMP]
общие_настройки_сетевого_оборудования_cisco [2022/03/31 10:44]
val [Использование RMON подсистемы протокола SNMP]
Line 156: Line 156:
 snmp-server host server writetrap snmp-server host server writetrap
  
-rmon event 1001 log trap writetrap description "​Critical ​out bandwith ​LAN int" +rmon event 1001 log trap writetrap description "​Critical ​input bandwith ​WAN int" 
-rmon event 1002 log trap writetrap description "​Ok ​out bandwith ​LAN int"+rmon event 1002 log trap writetrap description "​Ok ​input bandwith ​WAN int"
  
-rmon alarm 2002 1.3.6.1.2.1.2.2.1.16.2 ​8 delta rising-threshold 900000 1001 falling-threshold 300000 1002 +rmon alarm 2002 ifEntry.10.1 8 delta rising-threshold 900000 1001 falling-threshold 300000 1002 
-!rmon alarm 2002 ifEntry.10.1 8 delta rising-threshold 900000 1001 falling-threshold 300000 1002+!rmon alarm 2002 1.3.6.1.2.1.2.2.1.16.5 ​8 delta rising-threshold 900000 1001 falling-threshold 300000 1002
  
 router#show rmon alarms router#show rmon alarms